Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Distraction Osteogenesis for Implant Site Development Using a Novel Orthodontic Device: A Case Report
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 28 , Issue 2
March/April 2008

Pages 189-196


Distraction Osteogenesis for Implant Site Development Using a Novel Orthodontic Device: A Case Report

Italo Menini, MD, DDS/Claudio Zornitta, MD, DDS/Guido Menini, CDT


PMID: 18546815
DOI: 10.11607/prd.00.0792

The case report describes the distraction osteogenesis of a small bone fragment supporting a maxillary central incisor that had become ankylosed and infraoccluded after trauma. After initial orthodontic treatment, surgery was performed, entailing a trapezoidal osteotomy with minimal periosteal elevation through a horizontal incision. On this occasion, a device was applied, anchored to the tooth, and activated by a micrometer screw. On completion of distraction, the fragment was retained for 5 months. The ankylosed tooth was then removed, and an implant was inserted and provided with an immediate provisional prosthesis without occlusal loading. Five months later, a definitive prosthesis with occlusal loading was applied and is still in place 1 year later without any problems. (Int J Periodontics Restorative Dent 2008;28:189–196.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help